Configuration with ThinPrint Client Manager
ThinPrint Client Service Windows Manual 13
© Cortado AG 2012
Illus. 14
Illus. 15
Advanced tab
The ADVANCED panel (Illus. 16) offers the following settings:
Bandwidth Check this box and enter a bandwidth value. If the value is larger or if C
LIENT
C
ONTROL is disabled at the server, server settings (see ThinPrint Engine manual)
are applied.
TCP Port Enter here the port number where ThinPrint Client Service Windows should
receive incoming connections. Be sure: Same TCP port number for both Thin-
Print Client Service Windows and ThinPrint Engine printer port to which the cli-
ent printer is connected.
5
Otherwise, communication between the two Thin-
Print components is impossible. Default TCP port number is 4000. Make
certain that this port is open for both incoming and outgoing connections. If you
want to avoid that condition, you can use the ThinPrint Connection Service (out-
going connection only).
Note! Unlike printer names, class names may not be longer than 7 characters
and may not included blank spaces.
Illus. 14 Enter class name
(see AutoConnect in the
ThinPrint Engine manual;
Page 21
)
Illus. 15 Printers with ID and class
5 see also ThinPrint Engine manual